![background.jpg](https://static.wixstatic.com/media/24ecb6_15d5ea65b16c4444abda604ee6f85706~mv2.jpg/v1/fill/w_147,h_83,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/24ecb6_15d5ea65b16c4444abda604ee6f85706~mv2.jpg)
OUR CORE PRODUCT
Ampashield-Thermal™, thanks to nano-carbon enabled chemistry, increases the effective surface area of a substrate to which it is applied that promotes cooling via thermal convection and also increases surface emissivity that provides superior cooling via thermal radiation.
Ampashield-Thermal™ has a “microcellular foam texture” that can be considered as highly emissive nano-heat sink. Product can be applied using conventional air spray technology, dip coating, aerosol spray or markers.
![AmpaSHIELD-THERMAL_cmyk.png](https://static.wixstatic.com/media/24ecb6_0518cdd3bedc4713a647436fa83b9634~mv2.png/v1/fill/w_201,h_63,al_c,q_95,enc_auto/AmpaSHIELD-THERMAL_cmyk.png)
![Thermal1.png](https://static.wixstatic.com/media/24ecb6_59ef9472878d4d86973a0f7e854422f3~mv2.png/v1/fill/w_549,h_579,al_c,q_95,enc_auto/Thermal1.png)
![deposition.png](https://static.wixstatic.com/media/24ecb6_631dc24d93c8446dae075f6a3d8a952d~mv2.png/v1/fill/w_71,h_37,al_c,q_85,usm_0.66_1.00_0.01,blur_2,enc_auto/deposition.png)
![background.jpg](https://static.wixstatic.com/media/24ecb6_15d5ea65b16c4444abda604ee6f85706~mv2.jpg/v1/fill/w_147,h_83,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/24ecb6_15d5ea65b16c4444abda604ee6f85706~mv2.jpg)
![AmpaSHIELD-PLUS_cmyk.png](https://static.wixstatic.com/media/24ecb6_dd7eced7cc84487e835ddde47b360412~mv2.png/v1/fill/w_196,h_63,al_c,q_85,usm_0.66_1.00_0.01,blur_3,enc_auto/AmpaSHIELD-PLUS_cmyk.png)
CONDUCTIVE
OPTION
Ampashield-Plus™ has been introduced as an electrically conductive variation of our core product to combine thermal management with controllable sheet resistance making it especially attractive for any resistive conductors/heaters.
Ampashield-Plus™ provides sheet resistance at the level of 50Ω/sq. at 10μm
Product can be applied using conventional air spray technology, dip coating, aerosol spray or markers.
![deposition.png](https://static.wixstatic.com/media/24ecb6_631dc24d93c8446dae075f6a3d8a952d~mv2.png/v1/fill/w_67,h_35,al_c,q_85,usm_0.66_1.00_0.01,blur_2,enc_auto/deposition.png)
![Plus1.png](https://static.wixstatic.com/media/24ecb6_b8929359d67347cc8730603e9a684c5b~mv2.png/v1/crop/x_3,y_0,w_866,h_751/fill/w_67,h_58,al_c,q_85,usm_0.66_1.00_0.01,blur_2,enc_auto/Plus1.png)
![AmpaSHIELD-PLUS_cmyk.png](https://static.wixstatic.com/media/24ecb6_dd7eced7cc84487e835ddde47b360412~mv2.png/v1/fill/w_77,h_25,al_c,q_85,usm_0.66_1.00_0.01,blur_2,enc_auto/AmpaSHIELD-PLUS_cmyk.png)
PRODUCT FEATURES
![corner1.png](https://static.wixstatic.com/media/24ecb6_666b70bd1cb44205b1675da6bccdeb68~mv2.png/v1/fill/w_187,h_169,al_c,q_85,usm_0.66_1.00_0.01,blur_3,enc_auto/corner1.png)
![AmpaSHIELD-THERMAL_cmyk.png](https://static.wixstatic.com/media/24ecb6_0518cdd3bedc4713a647436fa83b9634~mv2.png/v1/fill/w_77,h_25,al_c,q_85,usm_0.66_1.00_0.01,blur_2,enc_auto/AmpaSHIELD-THERMAL_cmyk.png)
![](https://static.wixstatic.com/media/24ecb6_a5ccc47617e444858ce8ae94a5463a38f000.jpg/v1/fill/w_110,h_62,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/24ecb6_a5ccc47617e444858ce8ae94a5463a38f000.jpg)
![](https://static.wixstatic.com/media/24ecb6_8c3c367cda884f8a8806cb1036b54484f000.jpg/v1/fill/w_110,h_62,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/24ecb6_8c3c367cda884f8a8806cb1036b54484f000.jpg)
CAN BE APPLIED TO VARIETY OF SUBSTRATES ENABLING THEM TO HAVE ELECTRICAL CONDUCTIVITY
EASY TO APPLY BY CONVENTIONAL SPRAYING
(touch dry in less than 1 minute)
![](https://static.wixstatic.com/media/24ecb6_fabf353b3c574e24877b804223221416f000.jpg/v1/fill/w_110,h_62,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/24ecb6_fabf353b3c574e24877b804223221416f000.jpg)
![](https://static.wixstatic.com/media/24ecb6_8c08677a43574d849cce29c7e3c9b072f000.jpg/v1/fill/w_110,h_62,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/24ecb6_8c08677a43574d849cce29c7e3c9b072f000.jpg)
CAN BE USED TO PRODUCE FLEXIBLE RESISTIVE HEATERS
DOES NOT SUPPORT COMBUSTION AND AND DOES NOT DETERIORATE EASILY UNDER FIRE CONDITIONS
![](https://static.wixstatic.com/media/24ecb6_64474029dda1433a9fc45458f87fc32af000.jpg/v1/fill/w_110,h_62,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/24ecb6_64474029dda1433a9fc45458f87fc32af000.jpg)
EXCELLENT ADHESION, BENDING AND IMPACT RESISTANCE
![](https://static.wixstatic.com/media/24ecb6_84bde848ebe143aa87d7caf3e02d67b5f000.jpg/v1/fill/w_110,h_62,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/24ecb6_84bde848ebe143aa87d7caf3e02d67b5f000.jpg)
CAN BE USED TO PRODUCE FLEXIBLE
CONDUCTORS
THERMAL MANAGEMENT EXAMPLES
![Ampa.png](https://static.wixstatic.com/media/24ecb6_d42d063489224af9b5577785651d725e~mv2.png/v1/fill/w_118,h_134,al_c,q_85,usm_0.66_1.00_0.01,blur_3,enc_auto/Ampa.png)
![corner3.png](https://static.wixstatic.com/media/24ecb6_9c4b2fdc0d23430dad10c2ab7b4663d3~mv2.png/v1/fill/w_74,h_67,al_c,q_85,usm_0.66_1.00_0.01,blur_2,enc_auto/corner3.png)
Increasing current carrying capacity (ampacity) of copper conductors such as bus bars.
![ampacity.png](https://static.wixstatic.com/media/24ecb6_a17e3a6a2f5b42cabfed4813a7ee4a41~mv2.png/v1/fill/w_47,h_21,al_c,q_85,usm_0.66_1.00_0.01,blur_2,enc_auto/ampacity.png)
Case 1: Temperature of 25x0.7mm copper strip with and w/o coating under natural convection (no enclosure)
​
​
Case 2: Temperature of 25x0.7mm copper strip with and w/o coating under forced convection up to 3 m/s (200A, conductor inside 50 mm tube)
​
![ampacity2.png](https://static.wixstatic.com/media/24ecb6_7b0a6992ba1048f4b6ade835924e5176~mv2.png/v1/fill/w_48,h_21,al_c,q_85,usm_0.66_1.00_0.01,blur_2,enc_auto/ampacity2.png)
​
Case 3: Temperature of bare Cu conductor and metal enclosure under natural convection and 3 enclosure variants illustrated below
![Enclosure2.png](https://static.wixstatic.com/media/24ecb6_57aee6b4619e45e995104bce0fd0340c~mv2.png/v1/fill/w_47,h_23,al_c,q_85,usm_0.66_1.00_0.01,blur_2,enc_auto/Enclosure2.png)
![Enclosure.png](https://static.wixstatic.com/media/24ecb6_cf795573ab474448914b4d7fea36cd2e~mv2.png/v1/crop/x_37,y_0,w_1437,h_665/fill/w_47,h_22,al_c,q_85,usm_0.66_1.00_0.01,blur_2,enc_auto/Enclosure.png)
![enclosure3.png](https://static.wixstatic.com/media/24ecb6_aa5465b1400042349697344583a490bb~mv2.png/v1/fill/w_45,h_21,al_c,q_85,usm_0.66_1.00_0.01,blur_2,enc_auto/enclosure3.png)
![background.jpg](https://static.wixstatic.com/media/24ecb6_15d5ea65b16c4444abda604ee6f85706~mv2.jpg/v1/fill/w_147,h_83,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/24ecb6_15d5ea65b16c4444abda604ee6f85706~mv2.jpg)
![corner2.png](https://static.wixstatic.com/media/24ecb6_47c2c4f868bd4c0fab87f1e4937aff9b~mv2.png/v1/crop/x_0,y_0,w_620,h_533/fill/w_190,h_163,al_c,q_85,usm_0.66_1.00_0.01,blur_3,enc_auto/corner2.png)
![Ampa.png](https://static.wixstatic.com/media/24ecb6_d42d063489224af9b5577785651d725e~mv2.png/v1/fill/w_70,h_80,al_c,q_85,usm_0.66_1.00_0.01,blur_3,enc_auto/Ampa.png)
![corner2.png](https://static.wixstatic.com/media/24ecb6_47c2c4f868bd4c0fab87f1e4937aff9b~mv2.png/v1/crop/x_0,y_0,w_620,h_525/fill/w_50,h_43,al_c,q_85,usm_0.66_1.00_0.01,blur_2,enc_auto/corner2.png)
![Plus2.png](https://static.wixstatic.com/media/24ecb6_8d7013464bcd4de698793cda39c4daf5~mv2.png/v1/fill/w_67,h_80,al_c,q_85,usm_0.66_1.00_0.01,blur_3,enc_auto/Plus2.png)
EXEMPLARY APPLICATIONS
-
High ampacity Cu and Al bus bars
-
Radiators,
-
Low-profile heat exchangers
-
Passively-cooled embedded systems, e.g. LCD displays and other large electronics
-
Electronics cabinets/enclosures
-
High accuracy non-contact temperature measurements (using IR cameras)
![Cooling.png](https://static.wixstatic.com/media/24ecb6_09bffdacea4f4f96846392c8c531543f~mv2.png/v1/fill/w_78,h_75,al_c,q_85,usm_0.66_1.00_0.01,blur_2,enc_auto/Cooling.png)